Tungsten Heavy Powder, Inc. 9097 Kenamar Drive, San Diego, California 92121-2421, Tel. +1 858 693-6100, www.thpap.com

1Kg Technon® Poly KIT

Quantity : Plus Minus

ea
total
 

Technon® / Poly Test Kit Process Summary

Work Time: 1 hour

Technon® / Poly Test Kit Process Summary

Work Time:
 1 hour

Click here for printer-friendly mixing instructions.

  1. STEP 1. Drying the Technon®  powder is recommended for best results, but is not essential. To do so, heat the powder to 110°F (43°C) for about 1 hour and allow to cool to room temperature.
  2. STEP 2. Measure and pour the required amount of A and B poly components into the mixing container. The suggested ratio is 100 parts A to 20 parts B by weightSee photo below
  3. STEP 3. Mix by hand for about 15 seconds.
  4. STEP 4. Measure and add the required amount of Technon® powder to the mixing container. The suggested mixing ratio is 93.5% powder to 6.5% poly (A & B combined). See photo below
  5. STEP 5. Mix A and B poly components well with the Technon® powder for 5 – 10 seconds using a high shear mixer or 25 – 30 seconds by hand. See photos below
  6. STEP 6. Adjust the consistency by adding more powder to achieve the maximum density desired.
Consistency
by Application
Max. Density
After Curing
Poured 9.5 g/cc
Injected under pressure 10 g/cc
Filled as light paste 10.25 g/cc
Filled as heavy paste 10.50 g/cc
Spincast 11.50 g/cc
  1. STEP 7. Pour compound and allow to cure for 24 hours at room temperature. Alternatively, injection may also be used. See photos below

IMPORTANT: Please also see the Notes below.
Notes:

NOTES:

  • Vacuum degassing is not required
  • Curing by elevated temperatures is not recommended
  • Drying the powder is recommended for best results, but not essential
  • Store in a cool dry location. Unopened containers have a shelf life of 6 months from date of shipment, when properly stored
  • Purge opened containers with dry nitrogen before resealing

For production quantities, we can offer a unique system that allows mixing directly in the injector container (syringe) with a suitable mixing impeller. After mixing, simply withdraw the impeller, replace it with a push rod and a piston, attach a suitable nozzle (not shown), and inject.

Eco-Friendly: All components are reusable, with minimum wasted compound and an efficient production cycle time. Several container sizes are available.